The Evolution of Early Warning Detection
Closing the gaps in the market with innovation and quality.
Because when the priority is protecting the continuity of your business operations, waiting on passive smoke detection is simply not enough. The NFPA 75 and 76 regulations recommend the use of early warning aspirating smoke detectors to protect critical areas.
Early Warning Aspirating Smoke Detection


Aspiration detectors trigger alarms in the early stages or fire development, much before the fire starts. This allows us to act proactively and avoid having to react and control a potential fire. The time graph below shows the detection and control stages of fire protection.
Early warning smoke detectors function by actively aspirating and sampling the air in an enclosure, whereas passive photoelectric detectors must wait for the smoke to reach them. Beside the active nature of the detection, our aspirating detectors are on average 8,000× times more sensitive than a conventional detector.


Ultra Fast Detection
Very High Sensitivity
Maximum Protection
🚀
🎯
🛡️
AVA Aspirating Detectors
AVA detectors are the most advanced and precise aspirating smoke detectors currently on the market. with a huge range of solutions aimed at the effective protection of any size space.
With twice the sensitivity as the leading competitor, AVA brings more than just precision to the world of early warning smoke detection. All AVA detectors come with an Artificial Intelligence auto-learning algorithm that adjusts the behavior of the system based on its environment. They bring integrated temperature, humidity, and monoxide sensors to monitor a broader risk profile to ensure your operational continuity. AVA is the true evolution of the aspirating smoke detectors.




Detection for Small Enclosures
AVA is the pioneer in developing the world's first early warning aspirating smoke detector specifically designed to protect small enclosures. The CSD has miniature design can can be easily installed inside very tight spaces, such as small cabinets. It has a high sensitivity which not only achieves extremely early smoke detection, but it also has integrated temperature and humidity sensors so provide a truly comprehensive protection profile for your critical operations.
Compact design for protecting small spaces
Artificial Intelligence auto-learning algorithm
High detection sensitivity ( 0.005 % obs/ ft)
Integrated Temperature, Humidity, and Monoxide sensors
Non-intrusive direct in-cabinet installation
Seamless integration with suppression cylinders for direct activation
Coverage area of 100m2 (30m of linear tubbing & sampling points)
2 output relays and 1 GPI input relay
Remote display unit available




Detector Model: CSD-H10
Remote Display Model: RDU-PMC
Designed for Suppression Release
The AVA Cupid is the only early warning aspirating smoke detector in the market specifically designed for the control and activation of suppression systems in critical areas. The Cupid HM2 employs two completely independent detections chambers, each with its own sensor and aspirator, to create 2 distinct detections zones. This allows us to leverage a true crossed zone detection strategy to control suppression release, giving us the benefits of ultra early warning smoke detection but the reliability and control or crossed zone detection. Just liek the CSD detector, the Cupid also has integrated temperature and humidity sensors. This is crucial to provide a truly comprehensive protection profile for critical areas.
2 fully independent detection sensors for crossed zone detection & suppression control
Artificial Intelligence driven auto-learning algorithm
High detection sensitivity ( 0.005 % obs/ ft)
Independent Temperature, Humidity, and Monoxide sensors per pipe
Seamless integration with suppression cylinders for direct activation
Coverage areas of (HM1: 1000m2 / HM2: 2000m2)
4 output relays and 2 GPI input relay
Remote display unit available


Detector Model: HM2



CUPID True Crossed Zone Detection
Traditional Aspiration Detection
The Quartas models employ a high-power Blue LED ensuring exceptional sensitivity making it an optimal choice for protecting a wide range of spaces, from the small to very large. The Quartas Smart Smoke Level (SSL) algorithm automatically activates upon power-up of the device. Operating continuously, 24/7, it gathers data on background levels, ensuring consistent performance and minimizing nuisance alarms. The Quartas2000 model is your top choice for addressable detection, using its four separate aspirators and a proprietary algorithm to determine the source of the smoke.
Wide array of models to protect medium or very large spaces
Artificial Intelligence auto-learning algorithm (SSL)
Maximum detection sensitivity ( 0.00003 % obs/ ft)
Coverage area of 5700m2 (Q2000) / 1800m2 (Q500) / 1350m2 (Q300)
Linear pipe of 4 x 100m (Q2000) / 100m (Q500) / 75m (Q300)
Output relays 23 (Q2000) / 7 (Q500 / Q300)
GPI input relays 8 (Q2000) / 4 (Q500 / Q300)
Pipe addressability with 4 independent aspirators (Q2000)




Detector Model: Quartas-2000
Detector Model: Quartas-500
Detection for Very Large Enclosures
The AVA FANFARE is the first real multi-zone early warning aspiration detector for protecting large and very large enclosures. This detector was designed with large enclosures in mind. Engineering for the protection of spaces where traditional detection is difficult to install and maintain. The focus is to bring early warning smoke detection technology out of its traditional uses, such as data centers, into other critical infrastructure like airports, malls, and warehouses. The FANFARE ranges from 4 to 8 fully separate and independent zones, each equipped with its own sensor chamber, aspirator, and monitoring display.
4 or 8 fully independent zones for addressable detection
Artificial Intelligence driven auto-learning algorithm
Maximum detection sensitivity ( 0.00003 % obs/ ft)
Independent Temperature, Humidity, and Monoxide sensors per pipe
Huge coverage area: 16,000m2 (F-4000) / 8,000m2 (F-2000)
7 output relays
GPI input relays 8 (FANFARE-4000) / 4 (FANFARE-2000)


Detector Model: FANFARE-4000
COMING SOON...
Maximum Aspiration Power
The Hercules series uses a super high-powered aspirator safeguarding large-scale, high-risk environments. The enhanced aspirators allow for much longer pipe runs, making it ideal for protecting large expansive volumes such as airports, warehouses, storage facilities, shopping centers, hangars, cold storages and more. The Hercules brings all of the same technologies as the other AVA detectors, from AI drive auto-learning algorithms to independent temperature and humidity sensors per pipe.
4 fully independent zones for addressable detection
Ultra high pressure aspirators that allow for super long pipe runs
Artificial Intelligence auto-learning algorithm (SSL)
Maximum detection sensitivity ( 0.00003 % obs/ ft)
Independent Temperature, Humidity, and Monoxide sensors per pipe
Linear pipe runs of 4 x 200m


Detector Model: VX4
COMING SOON...
Detector Model: VX4C
Networking and Monitoring
AVA detectors integrate seamlessly into a unified network, providing real-time visibility of system status and events. Users can monitor alerts, fire signals, and faults while managing devices remotely with functions like reset, isolation, and mute. Combined with monitoring software and third-party interfaces, the system ensures smooth communication and efficient control for reliable fire protection management.
Real time live monitoring of up to 96 detectors
Intuitive 15.6” widescreen touch-screen display
HDMI output for connection with external monitors
Supports remote operations such as reset, isolation, etc
Native integration to the AVA AMS-0200 monitoring software
Robust password protected access control


AVA AMS-0200 monitoring software




Module Model: NIM-1000
Module Model: NICP-1215
Portable Fire Finder
The PASD portable fire finder is designed to quickly locate the exact source of a fire in its earliest stages, even in challenging environments with high airflow or hidden ignition points. By actively sampling air and using advanced blue-light detection, PASD can identify smoke particles invisible to the human eye and guide personnel directly to the source. Lightweight and easy to carry, it provides fast, reliable fire source detection across diverse applications, helping prevent false alarms and enabling quicker intervention when every second matters.
Pinpoints the exact origin of a fire, even in high-airflow spaces.
High detection sensitivity with blue light LED sensors
Portable design with shoulder strap and case for easy transport
Ideal for any application using an early warning detection system
Independent Temperature, Humidity, and Monoxide sensors per pipe
Easy air-sampling probe, clear display, and buzzer alarm for rapid decision-making.


Model: PASD-100